Regulation and data protection
This page briefly explains how software that tests attention or assesses attention-deficit/hyperactivity disorder (ADHD) is regulated in Turkey, the European Union (EU) and the US, and which rules apply to the data these tests produce, especially children's data. It is written for parents, clinicians and students who want to understand a product's regulatory status. The information is as of October 2026, and this page is not legal advice. Record numbers and decision dates for specific products are kept only on the Regulatory records page.
When is an attention test a medical device?
Turkey's Medical Device Regulation (Tıbbi Cihaz Yönetmeliği) and the EU's Medical Device Regulation (MDR) use the same definition: an instrument, apparatus or software that the manufacturer intends for a medical purpose, such as the diagnosis, prevention, monitoring, prediction, prognosis, treatment or alleviation of a disease, is a medical device (Tıbbi Cihaz Yönetmeliği, art. 3; MDR, art. 2(1)). What decides it is the intended purpose the manufacturer gives the product: the same kind of attention task falls into one category when offered as "train your attention" and into another when offered as "aids the assessment of ADHD".
In the US, the Food and Drug Administration (FDA) draws this line in its general wellness guidance. Software intended for maintaining or encouraging a healthy lifestyle, and unrelated to the diagnosis, treatment or prevention of a disease, is not a device by law. Under the current guidance, issued on 6 January 2026, products claiming to improve mental acuity, instruction following, concentration, problem-solving or multitasking, without reference to any disease, fall within this policy. The guidance also states that inclusion under the policy does not establish that a product has been shown to be safe or effective (FDA, 2026a).
The exercises on this site are not meant for diagnosis; how to read their results is on How to read your result.
Turkey: TİTCK and the Medical Device Regulation
- The regulation. Turkey's Medical Device Regulation was published in the Official Gazette (Resmî Gazete) on 2 June 2021 (no. 31499) and amended in 2022, 2023 and 2024. It uses the same classes and annex structure as the EU MDR: devices are classified as class I, IIa, IIb or III according to their intended purpose and risks, following the rules in its Annex VIII (art. 51). It also refers to obligations relating to EUDAMED, the EU's medical device database.
- TİTCK. The regulation is administered by the Turkish Medicines and Medical Devices Agency (Türkiye İlaç ve Tıbbi Cihaz Kurumu, TİTCK). TİTCK is also the authority that designates and monitors the conformity assessment bodies known as notified bodies (art. 35, art. 112).
- ÜTS registration. Manufacturers, importers and distributors established in Turkey, notified bodies and health institutions meet their device obligations through the national Product Tracking System (Ürün Takip Sistemi, ÜTS) (art. 34). According to TİTCK, device information can be queried in ÜTS, and there is a mobile app (TİTCK, ÜTS).
- Advertising. Devices that do not comply with the regulations may not be sold or advertised, and devices may not be advertised with false, misleading, exaggerated or unproven information (Regulation on the Sale, Advertising and Promotion of Medical Devices, art. 16; last amended on 3 July 2026).
European Union: the MDR and CE marking
- The regulation. Since 26 May 2021, medical devices in the EU have been governed by Regulation (EU) 2017/745, the MDR (Regulatory records).
- Rule 11 for software. Software intended to provide information used to take decisions with diagnostic or therapeutic purposes is class IIa. It is class III if such decisions may cause death or an irreversible deterioration of a person's health, and class IIb if they may cause a serious deterioration of health or a surgical intervention. Software intended to monitor physiological processes is class IIa (IIb for monitoring vital parameters); all other software is class I (MDR, Annex VIII, Rule 11). In an example from the software guidance of the EU's Medical Device Coordination Group (MDCG), software whose output a specialist uses to determine the necessary therapy is class IIa under Rule 11(a) (MDCG 2019-11 rev.1, June 2025).
- Who assesses it? Manufacturers of class I devices declare conformity themselves, except for sterile devices, devices with a measuring function and reusable surgical instruments. For class IIa and above, a notified body takes part in the conformity assessment (MDR, art. 52). The CE mark is the mark by which the manufacturer shows that the device conforms to these requirements (Tıbbi Cihaz Yönetmeliği, art. 3).
- EUDAMED. The EU's medical device database, where devices, manufacturers and certificates are registered. Which modules are mandatory, and since when, is on the regulatory records page.
- The simplification proposal. On 16 December 2025 the European Commission proposed a regulation to simplify the MDR (COM(2025) 1023). As of October 2026 the proposal is before the European Parliament and the Council and has not been adopted; to become binding, it must be adopted through the ordinary legislative procedure (European Commission, MDR overview).
- Artificial intelligence. Medical device software that uses artificial intelligence may also fall under the EU AI Act; the interplay between the two laws is covered in question-and-answer form in MDCG 2025-6 (June 2025; European Commission, MDCG guidance).
United States: the FDA
- Classes. The FDA places devices in three classes according to the level of control needed to assure safety and effectiveness: class I (general controls), class II (general and special controls) and class III (general controls and premarket approval) (FDA, Classify Your Medical Device).
- 510(k) (premarket notification). The manufacturer shows that its device is "substantially equivalent" to a device legally marketed in the US. If the FDA agrees, it sends an order letter allowing the device to be sold; this is a "clearance" (FDA, 510(k)).
- De Novo. The route by which new types of device, with no predicate to compare with, are classified into class I or II. A device classified this way can serve as a predicate for later 510(k) submissions (FDA, De Novo).
- Premarket approval (PMA). The FDA's scientific and regulatory review of the safety and effectiveness of class III devices (FDA, PMA).
- Clearance is not approval. Under FDA regulations, a 510(k) determination does not in any way denote official approval of a device; any representation that creates an impression of official approval because of it is misleading and constitutes misbranding (21 CFR 807.97).
- Clinical decision support software. Some clinical decision support software that meets certain criteria falls outside the device definition; the FDA's guidance on this was last issued in January 2026 (FDA, 2026b). How one test maker claims this route is shown on Regulatory records.
- AI and change control plans. The FDA's guidance on predetermined change control plans (PCCPs) for AI-enabled device software lets a manufacturer describe in advance the changes it plans to make and how they will be verified, so that changes made according to the plan can be implemented without a new marketing submission. The guidance was first issued on 4 December 2024; the current final version is dated 18 August 2025 (FDA, 2025).
Every diagnosis-related record for the products named on this site describes the product as an aid to clinical assessment, not as a stand-alone diagnostic tool; the records and their intended-use statements are on Regulatory records.
Children's data: KVKK
- Health data are a special category. Turkey's Law No. 6698 on the Protection of Personal Data (Kişisel Verilerin Korunması Kanunu, KVKK) treats health data as a special category of personal data and prohibits processing them. The exceptions include the data subject's explicit consent, and processing by persons under a duty of confidentiality or by authorised institutions for medical diagnosis, treatment and care (art. 6). This article, and article 9 on transfers abroad, were amended by Law No. 7499 on 2 March 2024. Data must be relevant, limited and proportionate to the purpose for which they are processed, and kept only as long as necessary (art. 4).
- No separate age for children. The text of the KVKK contains no provision or age threshold specific to children. Under the Turkish Civil Code, majority begins at age 18 (art. 11); the capacity to discern (ayırt etme gücü) is defined not by age but by the ability to act reasonably (art. 13); and minors who have this capacity do not need their legal representative's consent to exercise rights that are strictly personal (art. 16).
- A child's record in e-Nabız. Parents can access their children's health records through e-Nabız, the Ministry of Health's personal health record system, without needing consent; children with the capacity to discern can make this access subject to their permission. After a divorce, the parent granted custody can access the child's health data (Kişisel Sağlık Verileri Hakkında Yönetmelik [Regulation on Personal Health Data], art. 8; amended on 3 December 2025).
- A school decision. In 2020 the Turkish Personal Data Protection Board treated the results of a cognitive assessment test given at a school without a parent's explicit consent as health data, found the processing unlawful, and fined the school 50,000 Turkish lira (KVKK, 2020/255; details on The ethics of testing).
Children's data: the GDPR
- Health data. The EU's General Data Protection Regulation (GDPR) treats personal data related to a person's physical or mental health as health data (art. 4(15)) and prohibits processing this special category of data. The exceptions include explicit consent, and processing for medical diagnosis or the provision of health care on the basis of EU or member-state law or a contract with a health professional (art. 9).
- A child's consent. When an online service is offered directly to a child and processing relies on consent, it is lawful if the child is at least 16; below that age, consent must be given or authorised by the holder of parental responsibility. Member states may lower the age to 13 (art. 8).
- Specific protection. Children merit specific protection because they may be less aware of the risks to their personal data; this applies in particular to marketing and to creating personality or user profiles. Parental consent should not be necessary for preventive or counselling services offered directly to a child (recital 38).
- Data minimisation. Data must be adequate, relevant and limited to what is necessary for the purposes for which they are processed (art. 5(1)(c)).
What this site does with exercise results is on Privacy.
How can a product's registration be checked?
- Turkey: the public query screen of ÜTS (TİTCK, ÜTS).
- European Union: the public EUDAMED site (European Commission, EUDAMED).
- US and England: the FDA records, and the recommendations of England's National Institute for Health and Care Excellence (NICE), for the products named on this site are on Regulatory records.
What a record does and does not say about how good a test is: Evaluating a test. The ethical questions: The ethics of testing.
Sources
- 21 CFR 807.97, Misbranding by reference to premarket notification. Electronic Code of Federal Regulations. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-807/subpart-E/section-807.97
- European Commission. Medical Devices – New regulations: Overview. https://health.ec.europa.eu/medical-devices-new-regulations/overview_en
- European Commission. Medical Devices – EUDAMED: Overview. https://health.ec.europa.eu/medical-devices-eudamed/overview_en
- European Commission. Guidance – MDCG endorsed documents and other guidance (MDCG 2019-11 rev.1, MDCG 2025-6). https://health.ec.europa.eu/medical-devices-sector/new-regulations/guidance-mdcg-endorsed-documents-and-other-guidance_en
- European Parliament and Council (2016). Regulation (EU) 2016/679 (General Data Protection Regulation). https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32016R0679
- European Parliament and Council (2017). Regulation (EU) 2017/745 on medical devices (MDR). https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32017R0745
- FDA (2025). Marketing Submission Recommendations for a Predetermined Change Control Plan for Artificial Intelligence-Enabled Device Software Functions (18 August 2025; first issued 4 December 2024). https://www.fda.gov/regulatory-information/search-fda-guidance-documents/marketing-submission-recommendations-predetermined-change-control-plan-artificial-intelligence
- FDA (2026a). General Wellness: Policy for Low Risk Devices (6 January 2026). https://www.fda.gov/regulatory-information/search-fda-guidance-documents/general-wellness-policy-low-risk-devices
- FDA (2026b). Clinical Decision Support Software (January 2026). https://www.fda.gov/regulatory-information/search-fda-guidance-documents/clinical-decision-support-software
- FDA. Classify Your Medical Device. https://www.fda.gov/medical-devices/overview-device-regulation/classify-your-medical-device
- FDA. Premarket Notification 510(k). https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/premarket-notification-510k
- FDA. De Novo Classification Request. https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/de-novo-classification-request
- FDA. Premarket Approval (PMA). https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/premarket-approval-pma
- Kişisel Sağlık Verileri Hakkında Yönetmelik [Regulation on Personal Health Data]. Resmî Gazete, 21 June 2019, no. 30808 (current text, in Turkish). https://www.mevzuat.gov.tr/File/GeneratePdf?mevzuatNo=32610&mevzuatTur=KurumVeKurulusYonetmeligi&mevzuatTertip=5
- Kişisel Verileri Koruma Kurulu [Personal Data Protection Board] (2020). Decision summary no. 2020/255 of 2 April 2020 (in Turkish). https://www.kvkk.gov.tr/Icerik/6894/2020-255
- Law No. 4721, Turkish Civil Code (current text, in Turkish). https://www.mevzuat.gov.tr/mevzuatmetin/1.5.4721.pdf
- Law No. 6698 on the Protection of Personal Data (current text, in Turkish). https://www.mevzuat.gov.tr/mevzuatmetin/1.5.6698.pdf
- Tıbbi Cihaz Satış, Reklam ve Tanıtım Yönetmeliği [Regulation on the Sale, Advertising and Promotion of Medical Devices]. Resmî Gazete, 15 May 2014, no. 29001 (current text, in Turkish). https://www.mevzuat.gov.tr/File/GeneratePdf?mevzuatNo=19666&mevzuatTur=KurumVeKurulusYonetmeligi&mevzuatTertip=5
- Tıbbi Cihaz Yönetmeliği [Medical Device Regulation]. Resmî Gazete, 2 June 2021, no. 31499 (current text, in Turkish). https://www.mevzuat.gov.tr/File/GeneratePdf?mevzuatNo=38657&mevzuatTur=KurumVeKurulusYonetmeligi&mevzuatTertip=5
- TİTCK. Ürün Takip Sistemi (ÜTS) (in Turkish). https://www.titck.gov.tr/faaliyetalanlari/tibbicihaz/urun-takip-sistemi-uts
- TİTCK. ÜTS public query (in Turkish). https://utsuygulama.saglik.gov.tr/UTS/vatandas